Cable Calculator
General Notes:
- Multiple 24V DC fixtures can be connected to a single driver in parallel only.
- The total connected load of a circuit should not exceed the maximum driver load rating.
- We recommend running drivers at 80% of their maximum load rating to ensure heat and output performance are maximized.
- The required DC cable size should be calculated based on the connected load, cable length, voltage and allowable voltage drop percentage.
- Maximum Amp rating of the selected cable should be considered based total connected load.
- We recommend using a twin Sheath Automotive cable with a high strand count where applicable.
- We do NOT recommend using figure-8 cable or speaker cable.
- Please note that industry standard sizes/names do not match actual cable cross section area (CSA) measured in mm². Special care should be applied to ensure the correct cable size is selected.
- Please note that all the provided information by Tovo on this page is purely for guidance. All technical requirements for each installation/project should be carried out by a licensed Electrician/Electrical Engineer.
The Below table illustrates typical industry Automotive cable sizes with the corresponding cable cross section area (CSA) in mm², connected loads in Watts and their associated maximum cable lengths in meter, based on a allowable voltage drop of 5%
Industry Size | 2 mm | 3 mm | 4 mm | 5 mm | 6 mm | 8 B&S | 6 B&S |
---|---|---|---|---|---|---|---|
Cross-sectional area | 0.56 mm² | 1.13 mm² | 1.84 mm² | 2.9 mm² | 4.59 mm² | 7.71 mm² | 13.5 mm² |
10W | 32m | 91m | 151m | 240m | 378m | 600m | 1028m |
20W | 16m | 45m | 75m | 120m | 189m | 300m | 514m |
30W | 10m | 30m | 50m | 80m | 126m | 200m | 342m |
40W | 8m | 22m | 37m | 60m | 94m | 150m | 257m |
50W | 6m | 18m | 30m | 48m | 75m | 120m | 205m |
60W | 5m | 15m | 25m | 40m | 63m | 100m | 171m |
70W | 4m | 13m | 21m | 34m | 54m | 85m | 146m |
80W | 4m | 11m | 18m | 30m | 47m | 75m | 128m |
90W | 3m | 10m | 16m | 26m | 42m | 66m | 114m |
100W | 3m | 9m | 15m | 24m | 37m | 60m | 102m |
110W | 2m | 8m | 13m | 21m | 34m | 54m | 93m |
120W | 2m | 7m | 12m | 20m | 31m | 50m | 85m |
130W | 2m | 7m | 11m | 18m | 29m | 46m | 79m |
140W | 2m | 6m | 10m | 17m | 27m | 42m | 73m |
150W | 2m | 6m | 10m | 16m | 25m | 40m | 68m |
160W | 2m | 5m | 9m | 15m | 23m | 37m | 64m |
170W | 1m | 5m | 8m | 14m | 22m | 35m | 60m |
180W | 1m | 5m | 8m | 13m | 21m | 33m | 57m |
190W | 1m | 4m | 7m | 12m | 19m | 31m | 54m |
200W | 4m | 7m | 12m | 18m | 30m | 51m |
The Below table illustrates typical Instrumentation cable sizes in mm², connected loads in Watts and their associated maximum cable lengths in meter, based on a allowable voltage drop of 5%
Cross-sectional area | 0.5 mm² | 0.75 mm² | 1 mm² | 1.5 mm² | 2.5 mm² | 4 mm² | 6 mm² | 10 mm² |
---|---|---|---|---|---|---|---|---|
10W | 36m | 55m | 73m | 108m | 180m | 290m | 436m | 753m |
20W | 18m | 27m | 36m | 54m | 90m | 145m | 218m | 376m |
30W | 12m | 18m | 24m | 36m | 60m | 96m | 145m | 251m |
40W | 9m | 13m | 18m | 27m | 45m | 72m | 109m | 188m |
50W | 7m | 11m | 14m | 21m | 36m | 58m | 87m | 150m |
60W | 6m | 9m | 12m | 18m | 30m | 48m | 72m | 125m |
70W | 5m | 7m | 10m | 15m | 25m | 41m | 62m | 107m |
80W | 4m | 6m | 9m | 13m | 22m | 36m | 54m | 94m |
90W | 4m | 6m | 8m | 12m | 20m | 32m | 48m | 83m |
100W | 3m | 5m | 7m | 10m | 18m | 29m | 43m | 75m |
110W | 3m | 5m | 6m | 9m | 16m | 26m | 39m | 68m |
120W | 3m | 4m | 6m | 9m | 15m | 24m | 36m | 62m |
130W | 2m | 4m | 5m | 8m | 13m | 22m | 33m | 57m |
140W | 2m | 3m | 5m | 7m | 12m | 20m | 31m | 53m |
150W | 2m | 3m | 4m | 7m | 12m | 19m | 29m | 50m |
160W | 2m | 3m | 4m | 6m | 11m | 18m | 27m | 47m |
170W | 2m | 3m | 4m | 6m | 10m | 17m | 25m | 44m |
180W | 2m | 3m | 4m | 6m | 10m | 16m | 24m | 41m |
190W | 1m | 2m | 3m | 5m | 9m | 15m | 22m | 39m |
200W | 2m | 3m | 5m | 9m | 14m | 21m | 37m |